PURCHASING A NEW AIR CONDITIONING SYSTEM
•Buying New
•Service Information
•Air Conditioning Inspection
Air Conditioning Inspection
A
THOROUGH AIR CONDITIONING INSPECTION AND PRECISION ELECTRONIC TUNE UP
WILL TAKE ABOUT TWO HOURS
Many air conditioning inspections are designed to keep service personnel
busy during the slow season. It may also be used to help train less
experienced service persons. Air conditioning inspections are also
priced based on how much the average customer is willing to pay for
a the inspection.
If cost is an issue it is our opinion that a thorough air conditioning
inspection done every two or three years is a much better value than
a cursory inspection
that is done every year. Below is an example of a
Premium Air Conditioning inspection and precision electronic tune up.
Make ________________ Model ____________________________
Series ________________
Product #______ ____________________ ____
Serial ________________________________
Name Plate Compressor amperes_____
Condenser Fan Motor Amperes___
Maximum Fuse or circuit breaker Size ____
Minimum Ampacity ______
Clean Condenser coil _________
Ambient or Outside Temperature_____
Oil Condenser Fan Motor (If Possible) _____
Circuit Breaker or fuse size ____________
Disconnect switch ____________
Unit pad or support ______________
Check & tighten wiring connections ___
Check for burned wiring ____
Crankcase
Heater Amps. _
Compressor amperes: Common Terminal _____ Run Terminal ________
Start Terminal________
Compressor run capacitor rating ______MFD
Run Capacitor Amperes ___
Run Capacitor Voltage _____
2650 X Amperes/volts = ________ MFD.
VoltsCondenser Fan Motor Amperes: Common Terminal ___
Run Terminal ____ Start
Terminal____
High Pressure ____ PSIG Cond. Temp _____ Liquid Line Temp._____
Sub Cooling
Temp.____
Low Pressure_____PSIG Evap. Temp.____ Suction Line Temp. _____
Superheat Temp.
______
Capillary Tube System ___ Thermostatic Expansion Valve System ____ Refrigerant
Level ______
Check for Freon Leaks (15 minutes)__________________________
Change air filter_______
Return Air Temperature _____ Supply Air Temperature ____
Temperature Difference
________
Furnace Blower Motor Amperes ___ Oil Blower motor (If Possible) ___
Check Thermostat
______
Time Delay relay?_______ Air Flow Switch? ______ L.P. Switch?______
H.P. Switch?________
Comments You can watch us do the inspection and precision electronic tune up
if you want. We welcome comparison with other companies.
|